Merchandise Description
Edge OF DC Photo voltaic PUMP
one.Long term magnet DC brushless synchronous motor:The performance is enhanced by fifteen% – twenty%Conserve energyReduce the consumption of solar panels.
2.304 S/S pump shaft.
three.Brass or stainless metal outlet/connector/oil cylinder.
four.Japanese CZPT bearing:extend the working daily life.
five.LED screen demonstrates various knowledge such as electricity,voltage,current,velocity and error code and so on.
six.Alloy mechanical seal:Longer functioning life and higher reliability.
seven.Motor coil is produced by automatic winding device with centralized winding engineering,motor effectiveness is much enhanced.
eight.Intelligent h2o lack protection:The pump stops doing work routinely when there is no h2o in the nicely,and instantly commence working 30 minutes later.
nine.Controller:
(1)Watertight quality:IP65
(2)Ambient temperature:-15ºC~60ºC
(3)MPPT operate,the photo voltaic electrical power utilization price is larger.
(4)Automatic charging purpose:Ensure the pump typically working,in the meantime demand the batteryAnd when there is no sunshine,the battery can make the pump constantly functioning.
(5)LED displays the energy ,voltage,recent,pace etc working problem.
(6)Frequency conversion purpose:It can automatically run with frequency conversion in accordance to the photo voltaic power ,and person also can change the pace of pump manually.
(7)Routinely start and cease operating.
(8)Water-proof and leak-proofDouble seal result.
(9)Comfortable start:No impulse existing,safeguard the pump motor.
(ten)High voltage/Low voltage/In excess of-present/High temperature safety
10.2 years warranty.
Complex Data FOR 2DPC
Item | Type | Voltage | Greatest enter voltage(DC) |
Electricity | Max-Circulation | Max-Head | Outlet | Cable |
2DPC1.5-35-24-two hundred | Plastic Impeller | 24V | 30V-48V | 200W | one.5m³/h | 35m | .75” | 2m |
2DPC1.7-forty five-24-300 | Plastic Impeller | 24V | 30V-48V | 300W | 1.7m³/h | 45m | .75” | 2m |
2DPC1.7-sixty four-forty eight-400 | Plastic Impeller | 24V | 60V-90V | 400W | 1.7m³/h | 64m | .75” | 2m |
Technical Data FOR 3DSS
Merchandise | Sort | Voltage | Ideal enter voltage(DC) |
Electrical power | Max-Flow | Max-Head | Outlet | Cable |
3DSS0.5-28-twelve-80 | Screw | 12V | 20V-36V | 80W | .5m³/h | 28m | .75” | 2m |
3DSS1.2-56-24-a hundred and twenty | Screw | 24V | 30V-48V | 120W | one.2m³/h | 56m | .75” | 2m |
3DSS1.2-77-36-210 | Screw | 36V | 30V-48V | 210W | 1.2m³/h | 77m | .75” | 2m |
3DSS1.7-109-forty eight-500 | Screw | 48V | 60V-90V | 500W | one.7m³/h | 109m | .75” | 2m |
3DSS2.-150-forty eight-750 | Screw | 48V | 60V-90V | 750W | 2.0m³/h | 150m | .75” | 2m |
3DSS2.-one hundred fifty-seventy two-750 | Screw | 72V | 90V-120V | 750W | two.0m³/h | 150m | .75” | 2m |
3DSS2.2-a hundred and eighty-seventy two-1100 | Screw | 72V | 90V-120V | 1100W | two.2m³/h | 180m | .75” | 2m |
Specialized Information FOR 3DPC
Merchandise | Type | Voltage | Ideal input voltage(DC) |
Electricity | Max-Circulation | Max-Head | Outlet | Cable |
3DPC3-twenty five-24-200 | Plastic Impeller | 24V | 30V-48V | 200W | 3.0m³/h | 25m | 1.25” | 2m |
3DPC3-35-24-300 | Plastic Impeller | 24V | 30V-48V | 300W | three.0m³/h | 35m | 1.25” | 2m |
3DPC3.5-forty seven-48-400 | Plastic Impeller | 48V | 60V-90V | 400W | three.5m³/h | 47m | 1.25” | 2m |
3DPC3.5-eighty-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 3.5m³/h | 80m | 1.25” | 2m |
3DPC3.5-eighty-seventy two-600 | Plastic Impeller | 72V | 90V-120V | 600W | three.5m³/h | 80m | one.25” | 2m |
3DPC3.5-ninety five-48-750 | Plastic Impeller | 48V | 60V-90V | 750W | three.5m³/h | 95m | one.25” | 2m |
3DPC3.5-ninety five-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.8-123-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 3.8m³/h | 123m | one.25” | 2m |
3DPC3.8-123-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | three.8m³/h | 123m | one.25” | 2m |
3DPC3.8-a hundred and fifty five-one hundred ten-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | three.8m³/h | 155m | one.25” | 2m |
3DPC3.8-one hundred eighty-one hundred ten-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | three.8m³/h | 180m | one.25” | 2m |
Technological Info FOR 3DPC
Merchandise | Kind | Voltage | Best enter voltage(DC) |
Electricity | Max-Circulation | Max-Head | Outlet | Cable |
3DPC5-45-forty eight-500 | Plastic Impeller | 48V | 60V-90V | 500W | 3.0m³/h | 45m | 1.5” | 2m |
3DPC5.2-fifty-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 3.0m³/h | 50m | one.5” | 2m |
3DPC5.2-fifty-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | three.5m³/h | 50m | 1.5” | 2m |
3DPC5.2-seventy five-one hundred ten-750 | Plastic Impeller | 110V | 110V-150V | 750W | three.5m³/h | 75m | one.5” | 2m |
3DPC5.5-65-seventy two-750 | Plastic Impeller | 72V | 90V-120V | 750W | three.5m³/h | 65m | one.5” | 2m |
3DPC5.5-sixty five-one hundred ten-750 | Plastic Impeller | 110V | 110V-150V | 750W | three.5m³/h | 65m | one.5” | 2m |
3DPC6-eighty four-one hundred ten-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.5m³/h | 84m | 1.5” | 2m |
3DPC6-one hundred twenty five-a hundred and ten-1100 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 125m | 1.5” | 2m |
3DPC7-46-seventy two-750 | Plastic Impeller | 72V | 90V-120V | 750W | three.8m³/h | 46m | one.5” | 2m |
3DPC7-forty six-one hundred ten-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.8m³/h | 46m | 1.5” | 2m |
3DPC7.5-62-one hundred ten-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | three.8m³/h | 62m | 1.5” | 2m |
3DPC7.5-seventy eight-a hundred and ten-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | three.8m³/h | 78m | one.5” | 2m |
Specialized Info FOR 3DSC
Product | Sort | Voltage | Best enter voltage(DC) |
Electrical power | Max-Flow | Max-Head | Outlet | Cable |
3DSC4-35-24-300 | Stainless metal Impeller | 24V | 30V-48V | 300W | four.0m³/h | 35m | 1.25” | 2m |
3DSC4-fifty-forty eight-400 | Stainless steel Impeller | 48V | 60V-90V | 400W | four.0m³/h | 50m | one.25” | 2m |
3DSC4-80-48-400 | Stainless metal Impeller | 48V | 60V-90V | 600W | four.0m³/h | 80m | 1.25” | 2m |
3DSC4.8-ninety five-72-750 | Stainless steel Impeller | 72V | 90V-120V | 750W | 4.8m³/h | 95m | one.25” | 2m |
3DSC4.8-112-seventy two-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | four.8m³/h | 112m | one.25” | 2m |
3DSC4.8-112-one hundred ten-1100 | Stainless metal Impeller | 110V | 110V-150V | 1100W | four.8m³/h | 112m | 1.25” | 2m |
3DSC4.8-135-110-1500 | Stainless metal Impeller | 110V | 110V-150V | 1500W | 4.8m³/h | 135m | 1.25” | 2m |
Specialized Information FOR 4DPC
Product | Variety | Voltage | Ideal enter voltage(DC) |
Power | Max-Movement | Max-Head | Outlet | Cable |
4DPC6-forty two-forty eight-600 | Plastic Impeller | 48V | 60V-90V | 600W | six.0m³/h | 42m | one.25” | 2m |
4DPC6-42-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | six.0m³/h | 42m | one.25” | 2m |
4DPC6-fifty six-48-750 | Plastic Impeller | 48V | 60V-90V | 750W | six.0m³/h | 56m | 1.25” | 2m |
4DPC6-fifty six-seventy two-750 | Plastic Impeller | 72V | 90V-120V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-eighty four-seventy two-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | six.0m³/h | 84m | one.25” | 2m |
4DPC6-eighty four-a hundred and ten-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | six.0m³/h | 84m | 1.25” | 2m |
4DPC6-112-one hundred ten-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 6.0m³/h | 112m | one.25” | 2m |
4DPC6-one hundred thirty five-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 6.0m³/h | 135m | one.25” | 2m |
Complex Knowledge FOR 4DPC
Merchandise | Variety | Voltage | Best input voltage(DC) |
Power | Max-Movement | Max-Head | Outlet | Cable |
4DPC9-45-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | nine.0m³/h | 45m | 2” | 2m |
4DPC9-58-a hundred and ten-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | nine.0m³/h | 58m | 2” | 2m |
4DPC9-71-one hundred ten-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | nine.0m³/h | 71m | 2” | 2m |
4DPC9-eighty five-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | nine.0m³/h | 85m | 2” | 2m |
4DPC | Plastic Impeller | 110V | 110V-150V | 750W | thirteen.0m³/h | 36m | 2” | 2m |
4DPC | Plastic Impeller | 110V | 110V-150V | 1100W | 13.0m³/h | 49m | 2” | 2m |
4DPC | Plastic Impeller | 110V | 110V-150V | 1300W | 13.0m³/h | 54m | 2” | 2m |
4DPC | Plastic Impeller | 110V | 110V-150V | 1500W | thirteen.0m³/h | 60m | 2” | 2m |
4DPC | Plastic Impeller | 110V | 110V-150V | 1500W | seventeen.0m³/h | 48m | 2” | 2m |
Technical Information FOR 4DLR
Product | Variety | Voltage | Greatest enter voltage(DC) |
Power | Max-Movement | Max-Head | Outlet | Cable |
4DLR5-85-one hundred ten-750 | Plastic Impeller | 110V | 110V-150V | 750W | 5.0m³/h | 85m | 1.25” | 2m |
4DLR6-sixty five-seventy two-550 | Plastic Impeller | 72V | 90V-120V | 550W | six.0m³/h | 65m | 1.25” | 2m |
4DLR7.5-65-a hundred and ten-750 | Plastic Impeller | 110V | 110V-150V | 750W | 7.5m³/h | 65m | one.5” | 2m |
4DLR7.5-a hundred-seventy two-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | seven.5m³/h | 100m | 1.5” | 2m |
4DLR7.5-one hundred ten-one hundred ten-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | seven.5m³/h | 110m | 1.5” | 2m |
4DLR | Plastic Impeller | 72V | 90V-120V | 550W | 11.0m³/h | 45m | 2” | 2m |
4DLR | Plastic Impeller | 72V | 90V-120V | 1100W | twelve.0m³/h | 75m | 2” | 2m |
4DLR11.5-100-one hundred ten-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | eleven.5m³/h | 100m | 2” | 2m |
4DLR14.5-forty five-a hundred and ten-750 | Plastic Impeller | 110V | 110V-150V | 750W | 14.5m³/h | 45m | 2” | 2m |
4DLR | Plastic Impeller | 72V | 90V-120V | 1100W | 15.0m³/h | 55m | 2” | 2m |
4DLR15.5-70-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 15.5m³/h | 70m | 2” | 2m |
4DLR | Plastic Impeller | 110V | 110V-150V | 1500W | 20.0m³/h | 38m | 2” | 2m |
Specialized Data FOR 4DSC
Merchandise | Sort | Voltage | Best enter voltage(DC) |
Energy | Max-Circulation | Max-Head | Outlet | Cable |
4DSC5.2-45-48-five hundred | Stainless steel Impeller | 48V | 60V-90V | 500W | five.2m³/h | 45m | one.25” | 2m |
4DSC5.2-67-forty eight-750 | Stainless metal Impeller | 48V | 60V-90V | 750W | 5.2m³/h | 67m | one.25” | 2m |
4DSC5.2-sixty seven-seventy two-750 | Stainless steel Impeller | 72V | 90V-120V | 750W | 5.2m³/h | 67m | one.25” | 2m |
4DSC5.2-one zero one-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | five.2m³/h | 101m | 1.25” | 2m |
4DSC5.2-one zero one-110-1100 | Stainless steel Impeller | 110V | 110V-150V | 1100W | 5.2m³/h | 101m | one.25” | 2m |
4DSC5.2-146-110-1300 | Stainless metal Impeller | 110V | 110V-150V | 1300W | five.2m³/h | 146m | 1.25” | 2m |
4DSC4.8-203-a hundred and ten-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | four.8m³/h | 203m | one.25” | 2m |
4DSC7.5-eighty-110-1300 | Stainless metal Impeller | 110V | 110V-150V | 1300W | 7.5m³/h | 80m | one.25” | 2m |
4DSC7.5-100-110-1500 | Stainless metal Impeller | 110V | 110V-150V | 1500W | 7.5m³/h | 100m | one.25” | 2m |
Technical Data FOR 4DSC/4/6DSC
Item | Kind | Voltage | Greatest enter voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DSC | Stainless metal Impeller | 110V | 110V-150V | 1500W | eleven.0m³/h | 60m | 2” | 2m |
4DSC | Stainless metal Impeller | 110V | 110V-150V | 1500W | 19.0m³/h | 35m | 2” | 2m |
4DSC | Stainless steel Impeller | 110V | 110V-150V | 1500W | twenty five.0m³/h | 26m | 2” | 2m |
4/6DSC | Stainless metal Impeller | 72V | 90V-120V | 1100W | thirty.0m³/h | 19m | 2” | 2m |
four/6DSC | Stainless metal Impeller | 110V | 110V-150V | 1500W | 34.0m³/h | 22m | 2” | 2m |
Complex Knowledge FOR 3DPC-A/D
Item | Variety | Voltage | Greatest enter voltage(DC) |
Electrical power | Max-Movement | Max-Head | Outlet | Cable |
3DPC3.5-95-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | three.5m³/h | 95m | 1.25” | 2m |
3DPC3.8-123-one hundred fifty-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 3.8m³/h | 123m | one.25” | 2m |
3DPC3.8-155-one hundred fifty-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 3.8m³/h | 155m | 1.25” | 2m |
3DPC3.8-a hundred and eighty-two hundred-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 3.8m³/h | 180m | 1.25” | 2m |
3DPC5.2-seventy five-a hundred and ten-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 5.2m³/h | 75m | 1.5” | 2m |
3DPC5.5-sixty five-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 5.5m³/h | 65m | one.5” | 2m |
3DPC6-eighty four-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | six.0m³/h | 84m | 1.5” | 2m |
3DPC6-125-two hundred-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 6.0m³/h | 125m | one.5” | 2m |
3DPC7-46-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 7.0m³/h | 46m | one.5” | 2m |
3DPC7.5-62–one hundred fifty-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | seven.5m³/h | 62m | one.5” | 2m |
3DPC7.5-78-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 7.5m³/h | 78m | 1.5” | 2m |
Complex Information FOR 3DSC-A/D
Merchandise | Sort | Voltage | Ideal enter voltage(DC) |
Electricity | Max-Flow | Max-Head | Outlet | Cable |
3DSC4.8-95-one hundred ten-750-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 750W | four.8m³/h | 95m | one.25” | 2m |
3DSC4.8-110-a hundred and fifty-1100-A/D | Stainless metal Impeller | 110V-240V | 80V-400V | 1100W | four.8m³/h | 110m | 1.25” | 2m |
3DSC4.8-a hundred thirty-200-1500-A/D | Stainless metal Impeller | 110V-240V | 80V-400V | 1500W | four.8m³/h | 130m | one.25” | 2m |
Technological Data FOR 4DPC-A/D
Item | Kind | Voltage | Best enter voltage(DC) |
Electrical power | Max-Flow | Max-Head | Outlet | Cable |
4DPC6-56-one hundred ten-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 6.0m³/h | 56m | one.25” | 2m |
4DPC6-84-one hundred fifty-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 6.0m³/h | 84m | one.25” | 2m |
4DPC6-112-one hundred fifty-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 6.0m³/h | 112m | 1.25” | 2m |
4DPC6-135-two hundred-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 6.0m³/h | 135m | one.25” | 2m |
4DPC9-forty five-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | nine.0m³/h | 45m | 2” | 2m |
4DPC9-fifty eight-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 9.0m³/h | 58m | 2” | 2m |
4DPC9-71-one hundred fifty-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 9.0m³/h | 71m | 2” | 2m |
4DPC9-85-two hundred-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | nine.0m³/h | 85m | 2” | 2m |
4DPC-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 13.0m³/h | 36m | 2” | 2m |
4DPC-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | thirteen.0m³/h | 49m | 2” | 2m |
4DPC-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 13.0m³/h | 54m | 2” | 2m |
4DPC-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | thirteen.0m³/h | 60m | 2” | 2m |
4DPC-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 17.0m³/h | 48m | 2” | 2m |
FAQ:
Q: What is the shipping and delivery time?
A:The sample can be sent to buyer within 10-fifteen days.
The batch get can be transported inside 35 times following receiving deposit payment
Q:In which is your loading port?
A: HangZhou port, China
Q: Is it all appropriate to make customer’s own model name?
A: Can make OEM if get quantity attained 1000pcs totally
Q: What is your payment time period?
A: thirty% in progress, 70% stability the B/L or T/T
Q: What is the guarantee of the item?
A: We offer 1 yr solution existence assure and a generous 1 12 months warranty on all purchases that get started with the BL
Q: What data shall I supply you when I need to have your offer you?
A: Normally, we need to have consumer to offer the pump movement, total head, pump content (copper wire or aluminum wire? Stator size), voltage, frequency, and so forth, so we can quote precisely what buyer need to have
Q: Can you take customized merchandise?
A: Sure we settle for your specific purchase if you could give us with your demands.
Q: Will you offer any spare elements with the pumps?
A: Of course, we can provide for example: tank, flexible hose, stress change, stress gauge, brass connector, cable, and so on.
Q: Is there any leakage dilemma of this pump?
A: Some factory may have these kinds of dilemma, but we solved it very properly, by using very good content of pump casing, O-ring, and they match every single other excellent. We use 8 screw on the pump head although other individuals might use only 6 screw to help save price. We check a hundred% and lengthy time for the pump head element, to make certain there is no leakage problem.
Q: Do you supply sample?
A: We can offer sample, but client have to pay out for the sample fee
Q: What is the shipping and delivery time?
A:30-45 after we receiving your deposit.
Q:The place is your loading port?
A: HangZhou port, China
Q: Exactly where did you export to?
A: We export to more than 50 countries, for illustration, Israel, South Africa, Germany, Poland, Spain, Vietnam, Malaysia, Russia, Thailand, Mexico, Brazil, Chile, and so on.
Q: Can I get any discount if get CZPT PUMP model?
A: At the minute, consumer can get lower offer you if they obtain CZPT PUMP manufacturer but nevertheless get very same very good high quality pumps as always.
Q: Can I buy some force tank, adaptable hose, 5-way connector, stress gauge, stress controller and assemble with the pump?
A: Of course, numerous buyer acquire by this way, and we can make very excellent occupation to have this booster program to be assembled without having any issue.
Q: Can the pump be produced by tailored voltage and frequency
A: Of course, 220-240V, 110V, 50Hz, 60Hz, we can make in accordance to customer’s need to have
US $125-520 / Piece | |
1 Piece (Min. Order) |
###
Max.Head: | >150m |
---|---|
Max.Capacity: | >400 L/min |
Driving Type: | Motor |
Material: | Stainless Steel |
Structure: | Single-stage Pump |
Assembly: | Booster Pump |
###
Samples: |
US$ 250/Piece
1 Piece(Min.Order) |
---|
###
Customization: |
Available
|
---|
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
2DPC1.5-35-24-200 | Plastic Impeller | 24V | 30V-48V | 200W | 1.5m³/h | 35m | 0.75” | 2m |
2DPC1.7-45-24-300 | Plastic Impeller | 24V | 30V-48V | 300W | 1.7m³/h | 45m | 0.75” | 2m |
2DPC1.7-64-48-400 | Plastic Impeller | 24V | 60V-90V | 400W | 1.7m³/h | 64m | 0.75” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DSS0.5-28-12-80 | Screw | 12V | 20V-36V | 80W | 0.5m³/h | 28m | 0.75” | 2m |
3DSS1.2-56-24-120 | Screw | 24V | 30V-48V | 120W | 1.2m³/h | 56m | 0.75” | 2m |
3DSS1.2-77-36-210 | Screw | 36V | 30V-48V | 210W | 1.2m³/h | 77m | 0.75” | 2m |
3DSS1.7-109-48-500 | Screw | 48V | 60V-90V | 500W | 1.7m³/h | 109m | 0.75” | 2m |
3DSS2.0-150-48-750 | Screw | 48V | 60V-90V | 750W | 2.0m³/h | 150m | 0.75” | 2m |
3DSS2.0-150-72-750 | Screw | 72V | 90V-120V | 750W | 2.0m³/h | 150m | 0.75” | 2m |
3DSS2.2-180-72-1100 | Screw | 72V | 90V-120V | 1100W | 2.2m³/h | 180m | 0.75” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DPC3-25-24-200 | Plastic Impeller | 24V | 30V-48V | 200W | 3.0m³/h | 25m | 1.25” | 2m |
3DPC3-35-24-300 | Plastic Impeller | 24V | 30V-48V | 300W | 3.0m³/h | 35m | 1.25” | 2m |
3DPC3.5-47-48-400 | Plastic Impeller | 48V | 60V-90V | 400W | 3.5m³/h | 47m | 1.25” | 2m |
3DPC3.5-80-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 3.5m³/h | 80m | 1.25” | 2m |
3DPC3.5-80-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | 3.5m³/h | 80m | 1.25” | 2m |
3DPC3.5-95-48-750 | Plastic Impeller | 48V | 60V-90V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.5-95-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.8-123-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 3.8m³/h | 123m | 1.25” | 2m |
3DPC3.8-123-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.8m³/h | 123m | 1.25” | 2m |
3DPC3.8-155-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 3.8m³/h | 155m | 1.25” | 2m |
3DPC3.8-180-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 180m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DPC5-45-48-500 | Plastic Impeller | 48V | 60V-90V | 500W | 3.0m³/h | 45m | 1.5” | 2m |
3DPC5.2-50-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 3.0m³/h | 50m | 1.5” | 2m |
3DPC5.2-50-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | 3.5m³/h | 50m | 1.5” | 2m |
3DPC5.2-75-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.5m³/h | 75m | 1.5” | 2m |
3DPC5.5-65-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.5m³/h | 65m | 1.5” | 2m |
3DPC5.5-65-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.5m³/h | 65m | 1.5” | 2m |
3DPC6-84-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.5m³/h | 84m | 1.5” | 2m |
3DPC6-125-110-1100 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 125m | 1.5” | 2m |
3DPC7-46-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.8m³/h | 46m | 1.5” | 2m |
3DPC7-46-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.8m³/h | 46m | 1.5” | 2m |
3DPC7.5-62-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.8m³/h | 62m | 1.5” | 2m |
3DPC7.5-78-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 78m | 1.5” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DSC4-35-24-300 | Stainless steel Impeller | 24V | 30V-48V | 300W | 4.0m³/h | 35m | 1.25” | 2m |
3DSC4-50-48-400 | Stainless steel Impeller | 48V | 60V-90V | 400W | 4.0m³/h | 50m | 1.25” | 2m |
3DSC4-80-48-400 | Stainless steel Impeller | 48V | 60V-90V | 600W | 4.0m³/h | 80m | 1.25” | 2m |
3DSC4.8-95-72-750 | Stainless steel Impeller | 72V | 90V-120V | 750W | 4.8m³/h | 95m | 1.25” | 2m |
3DSC4.8-112-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | 4.8m³/h | 112m | 1.25” | 2m |
3DSC4.8-112-110-1100 | Stainless steel Impeller | 110V | 110V-150V | 1100W | 4.8m³/h | 112m | 1.25” | 2m |
3DSC4.8-135-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 4.8m³/h | 135m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DPC6-42-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 6.0m³/h | 42m | 1.25” | 2m |
4DPC6-42-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | 6.0m³/h | 42m | 1.25” | 2m |
4DPC6-56-48-750 | Plastic Impeller | 48V | 60V-90V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-56-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-84-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 6.0m³/h | 84m | 1.25” | 2m |
4DPC6-84-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 6.0m³/h | 84m | 1.25” | 2m |
4DPC6-112-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 6.0m³/h | 112m | 1.25” | 2m |
4DPC6-135-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 6.0m³/h | 135m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DPC9-45-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 9.0m³/h | 45m | 2” | 2m |
4DPC9-58-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 9.0m³/h | 58m | 2” | 2m |
4DPC9-71-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 9.0m³/h | 71m | 2” | 2m |
4DPC9-85-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 9.0m³/h | 85m | 2” | 2m |
4DPC13-36-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 13.0m³/h | 36m | 2” | 2m |
4DPC13-49-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 13.0m³/h | 49m | 2” | 2m |
4DPC13-54-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 13.0m³/h | 54m | 2” | 2m |
4DPC13-60-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 13.0m³/h | 60m | 2” | 2m |
4DPC17-48-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 17.0m³/h | 48m | 2” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DLR5-85-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 5.0m³/h | 85m | 1.25” | 2m |
4DLR6-65-72-550 | Plastic Impeller | 72V | 90V-120V | 550W | 6.0m³/h | 65m | 1.25” | 2m |
4DLR7.5-65-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 7.5m³/h | 65m | 1.5” | 2m |
4DLR7.5-100-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 7.5m³/h | 100m | 1.5” | 2m |
4DLR7.5-110-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 7.5m³/h | 110m | 1.5” | 2m |
4DLR11-45-72-550 | Plastic Impeller | 72V | 90V-120V | 550W | 11.0m³/h | 45m | 2” | 2m |
4DLR12-75-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 12.0m³/h | 75m | 2” | 2m |
4DLR11.5-100-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 11.5m³/h | 100m | 2” | 2m |
4DLR14.5-45-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 14.5m³/h | 45m | 2” | 2m |
4DLR15-55-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 15.0m³/h | 55m | 2” | 2m |
4DLR15.5-70-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 15.5m³/h | 70m | 2” | 2m |
4DLR20-38-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 20.0m³/h | 38m | 2” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DSC5.2-45-48-500 | Stainless steel Impeller | 48V | 60V-90V | 500W | 5.2m³/h | 45m | 1.25” | 2m |
4DSC5.2-67-48-750 | Stainless steel Impeller | 48V | 60V-90V | 750W | 5.2m³/h | 67m | 1.25” | 2m |
4DSC5.2-67-72-750 | Stainless steel Impeller | 72V | 90V-120V | 750W | 5.2m³/h | 67m | 1.25” | 2m |
4DSC5.2-101-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | 5.2m³/h | 101m | 1.25” | 2m |
4DSC5.2-101-110-1100 | Stainless steel Impeller | 110V | 110V-150V | 1100W | 5.2m³/h | 101m | 1.25” | 2m |
4DSC5.2-146-110-1300 | Stainless steel Impeller | 110V | 110V-150V | 1300W | 5.2m³/h | 146m | 1.25” | 2m |
4DSC4.8-203-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 4.8m³/h | 203m | 1.25” | 2m |
4DSC7.5-80-110-1300 | Stainless steel Impeller | 110V | 110V-150V | 1300W | 7.5m³/h | 80m | 1.25” | 2m |
4DSC7.5-100-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 7.5m³/h | 100m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DSC11-60-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 11.0m³/h | 60m | 2” | 2m |
4DSC19-35-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 19.0m³/h | 35m | 2” | 2m |
4DSC25-26-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 25.0m³/h | 26m | 2” | 2m |
4/6DSC30-19-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | 30.0m³/h | 19m | 2” | 2m |
4/6DSC34-22-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 34.0m³/h | 22m | 2” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DPC3.5-95-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.8-123-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 3.8m³/h | 123m | 1.25” | 2m |
3DPC3.8-155-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 3.8m³/h | 155m | 1.25” | 2m |
3DPC3.8-180-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 3.8m³/h | 180m | 1.25” | 2m |
3DPC5.2-75-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 5.2m³/h | 75m | 1.5” | 2m |
3DPC5.5-65-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 5.5m³/h | 65m | 1.5” | 2m |
3DPC6-84-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 6.0m³/h | 84m | 1.5” | 2m |
3DPC6-125-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 6.0m³/h | 125m | 1.5” | 2m |
3DPC7-46-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 7.0m³/h | 46m | 1.5” | 2m |
3DPC7.5-62–150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 7.5m³/h | 62m | 1.5” | 2m |
3DPC7.5-78-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 7.5m³/h | 78m | 1.5” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DSC4.8-95-110-750-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 750W | 4.8m³/h | 95m | 1.25” | 2m |
3DSC4.8-110-150-1100-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 1100W | 4.8m³/h | 110m | 1.25” | 2m |
3DSC4.8-130-200-1500-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 1500W | 4.8m³/h | 130m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DPC6-56-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-84-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 6.0m³/h | 84m | 1.25” | 2m |
4DPC6-112-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 6.0m³/h | 112m | 1.25” | 2m |
4DPC6-135-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 6.0m³/h | 135m | 1.25” | 2m |
4DPC9-45-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 9.0m³/h | 45m | 2” | 2m |
4DPC9-58-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 9.0m³/h | 58m | 2” | 2m |
4DPC9-71-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 9.0m³/h | 71m | 2” | 2m |
4DPC9-85-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 9.0m³/h | 85m | 2” | 2m |
4DPC13-36-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 13.0m³/h | 36m | 2” | 2m |
4DPC13-49-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 13.0m³/h | 49m | 2” | 2m |
4DPC13-54-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 13.0m³/h | 54m | 2” | 2m |
4DPC13-60-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 13.0m³/h | 60m | 2” | 2m |
4DPC17-48-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 17.0m³/h | 48m | 2” | 2m |
US $125-520 / Piece | |
1 Piece (Min. Order) |
###
Max.Head: | >150m |
---|---|
Max.Capacity: | >400 L/min |
Driving Type: | Motor |
Material: | Stainless Steel |
Structure: | Single-stage Pump |
Assembly: | Booster Pump |
###
Samples: |
US$ 250/Piece
1 Piece(Min.Order) |
---|
###
Customization: |
Available
|
---|
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
2DPC1.5-35-24-200 | Plastic Impeller | 24V | 30V-48V | 200W | 1.5m³/h | 35m | 0.75” | 2m |
2DPC1.7-45-24-300 | Plastic Impeller | 24V | 30V-48V | 300W | 1.7m³/h | 45m | 0.75” | 2m |
2DPC1.7-64-48-400 | Plastic Impeller | 24V | 60V-90V | 400W | 1.7m³/h | 64m | 0.75” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DSS0.5-28-12-80 | Screw | 12V | 20V-36V | 80W | 0.5m³/h | 28m | 0.75” | 2m |
3DSS1.2-56-24-120 | Screw | 24V | 30V-48V | 120W | 1.2m³/h | 56m | 0.75” | 2m |
3DSS1.2-77-36-210 | Screw | 36V | 30V-48V | 210W | 1.2m³/h | 77m | 0.75” | 2m |
3DSS1.7-109-48-500 | Screw | 48V | 60V-90V | 500W | 1.7m³/h | 109m | 0.75” | 2m |
3DSS2.0-150-48-750 | Screw | 48V | 60V-90V | 750W | 2.0m³/h | 150m | 0.75” | 2m |
3DSS2.0-150-72-750 | Screw | 72V | 90V-120V | 750W | 2.0m³/h | 150m | 0.75” | 2m |
3DSS2.2-180-72-1100 | Screw | 72V | 90V-120V | 1100W | 2.2m³/h | 180m | 0.75” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DPC3-25-24-200 | Plastic Impeller | 24V | 30V-48V | 200W | 3.0m³/h | 25m | 1.25” | 2m |
3DPC3-35-24-300 | Plastic Impeller | 24V | 30V-48V | 300W | 3.0m³/h | 35m | 1.25” | 2m |
3DPC3.5-47-48-400 | Plastic Impeller | 48V | 60V-90V | 400W | 3.5m³/h | 47m | 1.25” | 2m |
3DPC3.5-80-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 3.5m³/h | 80m | 1.25” | 2m |
3DPC3.5-80-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | 3.5m³/h | 80m | 1.25” | 2m |
3DPC3.5-95-48-750 | Plastic Impeller | 48V | 60V-90V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.5-95-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.8-123-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 3.8m³/h | 123m | 1.25” | 2m |
3DPC3.8-123-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.8m³/h | 123m | 1.25” | 2m |
3DPC3.8-155-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 3.8m³/h | 155m | 1.25” | 2m |
3DPC3.8-180-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 180m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DPC5-45-48-500 | Plastic Impeller | 48V | 60V-90V | 500W | 3.0m³/h | 45m | 1.5” | 2m |
3DPC5.2-50-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 3.0m³/h | 50m | 1.5” | 2m |
3DPC5.2-50-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | 3.5m³/h | 50m | 1.5” | 2m |
3DPC5.2-75-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.5m³/h | 75m | 1.5” | 2m |
3DPC5.5-65-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.5m³/h | 65m | 1.5” | 2m |
3DPC5.5-65-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.5m³/h | 65m | 1.5” | 2m |
3DPC6-84-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.5m³/h | 84m | 1.5” | 2m |
3DPC6-125-110-1100 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 125m | 1.5” | 2m |
3DPC7-46-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 3.8m³/h | 46m | 1.5” | 2m |
3DPC7-46-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 3.8m³/h | 46m | 1.5” | 2m |
3DPC7.5-62-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 3.8m³/h | 62m | 1.5” | 2m |
3DPC7.5-78-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 3.8m³/h | 78m | 1.5” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DSC4-35-24-300 | Stainless steel Impeller | 24V | 30V-48V | 300W | 4.0m³/h | 35m | 1.25” | 2m |
3DSC4-50-48-400 | Stainless steel Impeller | 48V | 60V-90V | 400W | 4.0m³/h | 50m | 1.25” | 2m |
3DSC4-80-48-400 | Stainless steel Impeller | 48V | 60V-90V | 600W | 4.0m³/h | 80m | 1.25” | 2m |
3DSC4.8-95-72-750 | Stainless steel Impeller | 72V | 90V-120V | 750W | 4.8m³/h | 95m | 1.25” | 2m |
3DSC4.8-112-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | 4.8m³/h | 112m | 1.25” | 2m |
3DSC4.8-112-110-1100 | Stainless steel Impeller | 110V | 110V-150V | 1100W | 4.8m³/h | 112m | 1.25” | 2m |
3DSC4.8-135-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 4.8m³/h | 135m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DPC6-42-48-600 | Plastic Impeller | 48V | 60V-90V | 600W | 6.0m³/h | 42m | 1.25” | 2m |
4DPC6-42-72-600 | Plastic Impeller | 72V | 90V-120V | 600W | 6.0m³/h | 42m | 1.25” | 2m |
4DPC6-56-48-750 | Plastic Impeller | 48V | 60V-90V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-56-72-750 | Plastic Impeller | 72V | 90V-120V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-84-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 6.0m³/h | 84m | 1.25” | 2m |
4DPC6-84-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 6.0m³/h | 84m | 1.25” | 2m |
4DPC6-112-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 6.0m³/h | 112m | 1.25” | 2m |
4DPC6-135-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 6.0m³/h | 135m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DPC9-45-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 9.0m³/h | 45m | 2” | 2m |
4DPC9-58-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 9.0m³/h | 58m | 2” | 2m |
4DPC9-71-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 9.0m³/h | 71m | 2” | 2m |
4DPC9-85-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 9.0m³/h | 85m | 2” | 2m |
4DPC13-36-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 13.0m³/h | 36m | 2” | 2m |
4DPC13-49-110-1100 | Plastic Impeller | 110V | 110V-150V | 1100W | 13.0m³/h | 49m | 2” | 2m |
4DPC13-54-110-1300 | Plastic Impeller | 110V | 110V-150V | 1300W | 13.0m³/h | 54m | 2” | 2m |
4DPC13-60-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 13.0m³/h | 60m | 2” | 2m |
4DPC17-48-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 17.0m³/h | 48m | 2” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DLR5-85-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 5.0m³/h | 85m | 1.25” | 2m |
4DLR6-65-72-550 | Plastic Impeller | 72V | 90V-120V | 550W | 6.0m³/h | 65m | 1.25” | 2m |
4DLR7.5-65-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 7.5m³/h | 65m | 1.5” | 2m |
4DLR7.5-100-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 7.5m³/h | 100m | 1.5” | 2m |
4DLR7.5-110-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 7.5m³/h | 110m | 1.5” | 2m |
4DLR11-45-72-550 | Plastic Impeller | 72V | 90V-120V | 550W | 11.0m³/h | 45m | 2” | 2m |
4DLR12-75-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 12.0m³/h | 75m | 2” | 2m |
4DLR11.5-100-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 11.5m³/h | 100m | 2” | 2m |
4DLR14.5-45-110-750 | Plastic Impeller | 110V | 110V-150V | 750W | 14.5m³/h | 45m | 2” | 2m |
4DLR15-55-72-1100 | Plastic Impeller | 72V | 90V-120V | 1100W | 15.0m³/h | 55m | 2” | 2m |
4DLR15.5-70-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 15.5m³/h | 70m | 2” | 2m |
4DLR20-38-110-1500 | Plastic Impeller | 110V | 110V-150V | 1500W | 20.0m³/h | 38m | 2” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DSC5.2-45-48-500 | Stainless steel Impeller | 48V | 60V-90V | 500W | 5.2m³/h | 45m | 1.25” | 2m |
4DSC5.2-67-48-750 | Stainless steel Impeller | 48V | 60V-90V | 750W | 5.2m³/h | 67m | 1.25” | 2m |
4DSC5.2-67-72-750 | Stainless steel Impeller | 72V | 90V-120V | 750W | 5.2m³/h | 67m | 1.25” | 2m |
4DSC5.2-101-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | 5.2m³/h | 101m | 1.25” | 2m |
4DSC5.2-101-110-1100 | Stainless steel Impeller | 110V | 110V-150V | 1100W | 5.2m³/h | 101m | 1.25” | 2m |
4DSC5.2-146-110-1300 | Stainless steel Impeller | 110V | 110V-150V | 1300W | 5.2m³/h | 146m | 1.25” | 2m |
4DSC4.8-203-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 4.8m³/h | 203m | 1.25” | 2m |
4DSC7.5-80-110-1300 | Stainless steel Impeller | 110V | 110V-150V | 1300W | 7.5m³/h | 80m | 1.25” | 2m |
4DSC7.5-100-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 7.5m³/h | 100m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DSC11-60-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 11.0m³/h | 60m | 2” | 2m |
4DSC19-35-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 19.0m³/h | 35m | 2” | 2m |
4DSC25-26-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 25.0m³/h | 26m | 2” | 2m |
4/6DSC30-19-72-1100 | Stainless steel Impeller | 72V | 90V-120V | 1100W | 30.0m³/h | 19m | 2” | 2m |
4/6DSC34-22-110-1500 | Stainless steel Impeller | 110V | 110V-150V | 1500W | 34.0m³/h | 22m | 2” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DPC3.5-95-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 3.5m³/h | 95m | 1.25” | 2m |
3DPC3.8-123-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 3.8m³/h | 123m | 1.25” | 2m |
3DPC3.8-155-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 3.8m³/h | 155m | 1.25” | 2m |
3DPC3.8-180-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 3.8m³/h | 180m | 1.25” | 2m |
3DPC5.2-75-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 5.2m³/h | 75m | 1.5” | 2m |
3DPC5.5-65-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 5.5m³/h | 65m | 1.5” | 2m |
3DPC6-84-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 6.0m³/h | 84m | 1.5” | 2m |
3DPC6-125-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 6.0m³/h | 125m | 1.5” | 2m |
3DPC7-46-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 7.0m³/h | 46m | 1.5” | 2m |
3DPC7.5-62–150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 7.5m³/h | 62m | 1.5” | 2m |
3DPC7.5-78-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 7.5m³/h | 78m | 1.5” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
3DSC4.8-95-110-750-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 750W | 4.8m³/h | 95m | 1.25” | 2m |
3DSC4.8-110-150-1100-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 1100W | 4.8m³/h | 110m | 1.25” | 2m |
3DSC4.8-130-200-1500-A/D | Stainless steel Impeller | 110V-240V | 80V-400V | 1500W | 4.8m³/h | 130m | 1.25” | 2m |
###
ITEM | Type | Voltage | Best input voltage(DC) |
Power | Max-Flow | Max-Head | Outlet | Cable |
4DPC6-56-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 6.0m³/h | 56m | 1.25” | 2m |
4DPC6-84-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 6.0m³/h | 84m | 1.25” | 2m |
4DPC6-112-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 6.0m³/h | 112m | 1.25” | 2m |
4DPC6-135-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 6.0m³/h | 135m | 1.25” | 2m |
4DPC9-45-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 9.0m³/h | 45m | 2” | 2m |
4DPC9-58-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 9.0m³/h | 58m | 2” | 2m |
4DPC9-71-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 9.0m³/h | 71m | 2” | 2m |
4DPC9-85-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 9.0m³/h | 85m | 2” | 2m |
4DPC13-36-110-750-A/D | Plastic Impeller | 110V-240V | 80V-400V | 750W | 13.0m³/h | 36m | 2” | 2m |
4DPC13-49-150-1100-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1100W | 13.0m³/h | 49m | 2” | 2m |
4DPC13-54-150-1300-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1300W | 13.0m³/h | 54m | 2” | 2m |
4DPC13-60-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 13.0m³/h | 60m | 2” | 2m |
4DPC17-48-200-1500-A/D | Plastic Impeller | 110V-240V | 80V-400V | 1500W | 17.0m³/h | 48m | 2” | 2m |
The Mechanical Advantage of a Pulley
A pulley is an important tool for many tasks. The advantage that it offers over a hand-held mechanism is its mechanical advantage. In this article, we’ll discuss the types of pulleys and their applications. We’ll also look at the types of compound pulleys. And, of course, there’s a little bit about the mechanical advantage of a pulley. This article will help you decide whether this tool is right for your needs.
Mechanical advantage of a pulley
A pulley has a mechanical advantage over a lever because it is able to produce more force over longer distances. The mechanical advantage of a pulley sounds brilliant and could produce energy. But what exactly is this mechanical advantage? Let’s take a look. First, consider how a pulley works. A rope supports a 100kg mass, which requires 500 newtons of force to lift. If the rope supports a 100kg mass, two sections of rope can support that load. Using a pulley, you can lift the same weight with half the force.
A pulley’s ideal mechanical advantage is the ratio of the force applied to the total length of the rope. The larger the radius, the greater the mechanical advantage. A pulley made up of four rope segments has an ideal mechanical advantage of four. Therefore, a four-segment pulley would multiply the force applied by four. As the numbers on the rope segments are smaller than the total length of the rope, it would be better to use a compound pulley.
The mechanical advantage of a pulley can be calculated by using the T-method. The first step in calculating the mechanical advantage of a pulley is defining the force you need to lift. Then, divide that force by two to calculate the amount of force you need to lift the load. Once you know this amount, you can design a pulley to meet your needs. That way, you can achieve the perfect balance between the two types of pulleys.
Types of pulleys
The main function of the pulley is to change the direction of the force. The mechanical advantages of a single pulley are two. Ideally, two pulleys should have two or more mechanical advantages. The mechanical advantage of compound pulleys can be increased to two or more. The number of pulleys that make up the composite pulley will determine the mechanical advantage. Certain types of pulleys are combined in one housing.
A stepped pulley is a set of pulleys with stepped surfaces. Each face is anchored to the mid-axis in an ordered sequence. This design gives these pulleys their name. They are used to increase and decrease the speed of the driven pulley. Step pulleys are usually used in pairs. They can be straight or stepped, but usually come in pairs.
The three main types of pulleys are pulleys, rope pulleys, and chain pulleys. Pulley Pulley systems use mechanics to lift and lower heavy objects. The Greek historian Plutarch credits the invention of the pulley to Archimedes of ancient Sicily. The Mesopotamians used rope pulleys to lift water around 1500 BC, and Stonehenge is said to have been built using a rope pulley system.
Application of pulley system
The advantages of using a pulley system are numerous. The ability to lift heavy objects is a good example. The pulley system makes it easy for people to lift blocks and other large objects. It can be used in many different applications, from utility elevators to construction cranes. In addition, it is widely used on sailing boats. If you want to learn more about the benefits of a pulley system, keep reading!
You can use the pulley system to water flowers or water plants. Some of them even lowered the pot to make cleaning easier. Pendant lights are another great place to install a pulley system. Climbing and fishing are just some of the activities that utilize the pulley. They are great for fishing and gardening. And since they are so versatile, you can use the pulley system anywhere.
To get the most out of your pulley system, you must choose a product that has all of the above attributes. A high-quality pulley must have a large pulley diameter and be made of sturdy materials. The cables must also be properly supported in the pulleys to ensure a long service life for your investment. A good cable should have minimal cracks and be lubricated. These factors are the most important considerations when choosing a pulley system for your needs.
composite pulley
Composite pulley systems combine two or more movable pulleys. These systems maximize the force to move the weight and can also change direction so they can be used to lift weights. Composite pulley systems can be as simple or as complex as your needs. For example, a pulley pulley system uses multiple pulleys on each axis. This method is often used for hoisting building materials.
A compound pulley system has two or more rope segments, each of which is pulled up on a load. It can increase lift by making objects move faster. These systems are common on large sailboats and construction sites. Composite pulleys are also available for larger boats. Due to their versatility, they are versatile tools for construction sites and large sailboats. If you have their app, you should consider buying one.
The main advantage of composite pulleys is their versatility. You can use them to lift weights or use them to save energy. Composite pulleys are especially useful for lifting heavy objects. For example, you can tie a paper clip to the end of the rope and pull it up. The flag is then lifted into the air with the help of compound pulleys. Composite pulleys are a great invention and they are often used in construction.
security considerations
There are several safety considerations to consider when using pulleys. The first is Secure Workload (SWL). This value is a general guideline for the maximum weight a pulley can safely handle. It varies according to the height and angle of the pulley. Besides SWL, there are some other factors to consider. Consider each one before deciding on the pulley that best suits your needs.
Another safety consideration is the weight of the load. Since the highs of the pulley are higher than the lows, it doubles in weight. The weight of the high point should not exceed 4 kN. The safety factor is calculated by multiplying the strength of the pulley by the weight of the load. Secondary COD has a safety factor of 10:1 and bulletproof primary anchors should be used with pulleys.
If using a chain hoist, you must be trained in the appropriate type of lifting. It is important not to hang on the top hooks of the structure, nor to overload or rig the hooks with multiple slings. You should also avoid corroded or damaged chains, as they can cause the crane to jam or overload. A worn chain can even cause the load to drop.
Components of a pulley system
Proper design of the pulley system can increase the life of the cables and pulleys. Larger diameter cables should be selected as they are more durable than smaller diameter cables. The cables should also be supported in the pulley grooves. The pulley must be designed to be compatible with the cable and its lubrication should be optimal. Proper lubrication of cables and pulleys will ensure maximum durability and longevity.
The first type of pulley is called a fast pulley. These pulleys are used for quick start and stop of the machine. These pulleys are usually mounted in pairs on the countershaft of the machine. One pulley is tightly mounted on the machine shaft, while the other pulley is fitted with a free-spinning mechanism. When the machine is running, the belt is mounted on the tensioner pulley, and when it is stopped, the belt slides on the independent pulley.
Composite pulley sets reduce the overall effort required by reducing the size of the pulley. These are usually attributed to Archimedes. Flat pulleys are often used in flat belt driven transmission systems. These are used in high-speed, low-power applications. Flat pulley idlers are also used on the back of traditional V-belts.
editor by czh 2022-11-29